Evaluasi Kinerja Struktur pada Gedung Eksisting Tujuh Lantai dengan FEMA 310

Nur Khotimah Handayani

Abstract


FEMA 310 guides in evaluating the performance of existing building structures where the Indonesian code has not provided standard rules for it. FEMA 310 is used to evaluate an existing seven-story building in Barek, Yogyakarta which has limited ductility. FEMA 310 consists of 3 stages, namely Tier 1, Tier 2, and Tier 3. This study is devoted to comparing the evaluation of Tier 2 results (linear static procedures) with Tier 3 results (nonlinear static procedures). The results have shown that the Tier 2 evaluation is well correlated with Tier 3 for the case of a seven-story building with limited ductility. This confirms that Tier 2 evaluations are capable to provide performance evaluations for low-rise to medium-rise buildings with limited ductility capacity.

Full Text:

PDF

References


Sucuoğlu, H., Gür, T., Günay, M.S. 2004. Performance-based seismic rehabilitation of damaged reinforced concrete buildings. Journal of Structural Engineering, Vol. 130, No. 1, hal 1475-1486.

FEMA 310, 1998, Handbook for the Seismic Evaluation of Buildings, ASCE for the Federal Emergency Management Agency, Washington, D.C.

Triwiyono, A. dan Santoso, B., 2010, Laporan Hitungan Struktur Gedung Asrama Mahasiswa MM UGM Barek Yogyakarta, Universitas Gadjah Mada, Yogyakarta.

Saputra, A., dkk., 2016, Laporan pengujian Hammer Test dan Core drill Gedung Asrama Mahasiswa UGM Kinanti dan Sendowo, Universitas Gadjah Mada, Yogyakarta.

Saputra, A., 2016, Analisis struktur gedung Asrama Mahasiswa UGM Kinanti dan Sendowo dan Perkuatannya, Universitas Gadjah Mada, Yogyakarta.

Afriandini, B., 2016, Analisis respon dinamik getaran mikro gedung Asrama Mahasiswa Kinanti UGM, Thesis, Program Pascasarjana Fakultas Teknik, Universitas Gadjah Mada, Yogyakarta.

Priyosulistyo, H., 2014, Analisis Dinamik Struktur. Diktat Ajar Mata Kuliah Analisis Dinamik Struktur Pascasarjana Jurusan Teknik Sipil dan Lingkungan, Universitas Gadjah Mada, Yogyakarta.

Applied Technology Council, 1996, Seismic evaluation and retrofit of concrete buildings, ATC 40, Vol. 1, Washington, D.C.

FEMA 356, 2000, Pre-standard and commentary for the seismic rehabilitation of buildings, ASCE for the Federal Emergency Management Agency, Washington, D.C.

Badan Standardisasi Nasional, 2012, SNI 1726:2012: Tata cara perencanaan ketahanan gempa untuk struktur bangunan gedung dan non gedung, Badan Standardisasi Nasional, Jakarta.

Çavdar, Ö. dan Bayraktar, A., 2016, Nonlinear Earthquake Performance Evaluation of a Structure Collapsed during the Van, Turkey, Earthquake on October 23, 2011, Journal of Performance of Constructed Facilities, Vol.30, No.4.

Satyarno, I., 2002, Analisis Dinamik Struktur dan Teknik Gempa, Departemen Teknik Sipil dan Lingkungan Fakultas Teknik UGM, Yogyakarta.

Pusat Penelitian Mitigasi Bencana Institut Teknologi Bandung (PPMB-ITB) dengan Pusat Penelitian dan Pengembangan Permukiman - Kementerian Pekerjaan Umum, 2011, Desain Spektra Indonesia, http://puskim.pu.go.id/Aplikasi/desain_spektra_indonesia_2011/, diakses 5 Februari 2018.




DOI: https://doi.org/10.35308/jts-utu.v7i1.3252

Refbacks

  • There are currently no refbacks.


Copyright (c) 2021 Jurnal Teknik Sipil dan Teknologi Konstruksi